Aluminum block bath Cool thermo unit CTU-Neo

Harga: Call Us
Aluminum block bath Cool thermo unit CTU-Neo

Aluminum block bath Cool thermo unit CTU-Neo


Applicable to isothermal gene amplification by programming. Quick temperature transition, a lot of exchange block.



Operation panel

Main Application

Various enzyme reaction and heat denaturation DNA/RNA
Ligation of DNA [CTU-Mini]
Gene amplification by LAMP method, whole gene amplification and so on

Features

Large enough size for half block x 2 or full block x 1

It can have one of Full block which can have 40 of 1.5ml micro tubes. It also can have two of Half block which is common use with Mini and can use two types of container.


Meet to various containers with exchanging block

We have a several half blocks (option) to meet with various containers. Full block for 0.2ml micro tube can have PCR plate as well. For detail please see next page.


Two types with different temperature range, Cooling type adopts Peltier system

There are DTU-Mini which is usable from Room temperature +3ºC, CTU-Mini which can handle low temperature by cooling with environmental friendly and energy saving Peltier heating and cooling system. Either one have improved temperature transition velocity.


Temperature programming with wait function

Wait function which wait timer count until temperature reach to setting value is equipped. Together with improved temperature transition velocity, it can perform accurate temperature change at isothermal gene amplification.


Specifications

ModelCTU-Neo
Temperature Range0ºC - +105 ºC
Temp. Control Accuracy±0.1ºC - +0.2 ºC
Temperature transition time (environmental temperature: +25 ºC)37ºC --> 100ºC/ about 20min (when using B-1140)
37ºC --> 4ºC/ about 20min (when using B-1140)
Minimum temperature setting unit0.1 ºC
Temperature settingUp and down setting
Temperature DisplayDigital display (setting temperature and current temperature)
Heating-Cooling SystemHeating and cooling by Peltier device
Programming Function2memory, 9 segment, wait function, setting time: 0 - 99hrs 59min
Safety device / functionFuse, overvoltage protection, over current protection, overheat, sensor error, nonvolatile memory error, protection of sample (high/low temperature), high temperature cutout
Dimensions210 x 268 x 175Hmm
WeightApprox. 4kg (exclude block)
Power SupplyAC100V 2A
Standard AccessoryHook handle for taking block out
●With open cover and environment over +30ºC, sometimes specifications doesn’t meet.