Temperature gradient gel electrophoresis device Micro TG Micro TG
Temperature gradient gel electrophoresis device Micro TG Micro TG
Temperature gradient gel electrophoresis becomes overwhelmingly simple!! No need of circulation device, electrophoresis finishes about 20min.Just putting holder with gel on thermo stage |
Main Application
●Point mutation and SNP analysis●Structure analysis of micro-biocenose by dissolution of 16S rDNA
●Pre identify of organism by genome profiling method
(*) In parallel type, segregation range is limited because of relation of migration distance
Features
By original micro-gel, migration time is within 20min
Using 2.5cm each micro-gel (polyacrylamide gel) which is made inside plastic gel cassette, TGGE and DNA-PAGE at constant temperature can be done easily. To make micro-gel, use optional gel caster.Compact design, No need of circulation device
This product is compactly designed and takes area of only a little more than A4 paper. Since it has temperature controlling function by Peltier device, there is no need of circulation device. Only device required other than Micro TG is power supply for electrophoresis (for example AE-8135/ 8155).3 micro-gels can undergo electrophoresis together
To perform electrophoresis, only things to do are set micro-gel and buffer wick on holder and then put on thermo stage. 3 micro-gels can migrate under same temperature gradient/ voltage condition. Accuracy of temperature gradient is almost identical in these 3 gels.Specifications
Model | Micro TG |
Temperature Range | +10ºC - +80ºC |
Temp. Control Accuracy | ±0.1ºC(*1) |
Maximum temperature gradient | 70 ºC (linearity holding temperature gradient 40 ºC) |
Maximum gel load | 3 |
Safety device / function | Electrophoresis can be done only when lid is open, error display |
Dimensions | 230 x 346 x 231Hmm |
Power Supply | AC100V 6A (except power supply for electrophoresis) |
Standard Accessory | Gel holder: Parallel TGGE x 3, Vertical TGGE x 3, Heat transmission sheet x 4, Cover film x 10, Buffer wick x 100 (*2) |
Additional essential product | Power supply, Gel cassette, Gel caster |
(*1) Temperature accuracy for gel is ±0.2 ºC for inside gel and ±0.5 ºC for between gels. Please use in air conditioned room. Though avoid place like near outlet of air conditioner where wind is directly blow.
(*2) Buffer wick (migration buffer carrier) can be used couple of times with rinsing by distilled water.
(*2) Buffer wick (migration buffer carrier) can be used couple of times with rinsing by distilled water.