VENTICELL®707-ECO line

 

VENTICELL®707-ECO line  
Features 
precise and fast laboratory drying oven
chamber volume 707 litres
temperature range from 10°C above ambient to 250/300°C
forced air circulation system in the chamber guarantees homogeneous temperature distribution in all the processes of drying, heating and sterilization of materials in laboratories
high operation comfort, precise temperature control and short chamber temperature equalization times after the door opening
higher speed and accuracy of all the tempering procedures ensures economical operation, especially suitable for high humidity materials, for demanding and accurate tests and processes
wide selection of optional equipment and accessories
output for connecting a printer or PC
possibility of validation (IQ, OQ) 

Specification 
  1. Interior of stainless steel material No. 1.4301
  2. Volume: 707 l
  3. Depth: 520 mm
  4. Width: 940 mm
  5. Height: 1410 mm
  6. Trays standard equipment: 2 pcs
  7. Storage area (w × d): 920 × 485 mm
  8. Racks: 19 max. number, distance between guide rails: 70 mm
  9. Maximal weight of the load inside the oven: 130 kg/oven, per tray: 50 kg/tray
  10. Number of external metal doors: 2 pcs
  11. External dimensions (including door and handle) depth: 790 mm
  12. Diameter of the air branch outer/inner: 52 / 49 mm, width: 1160 mm
  13. Height (inclusive foots – N): 1910 (N) mm
  14. From 10 °C above ambient temperature to: 250 °C
  15. Temperature accuracy according to DIN 12 880 T2, at working temperature with closed air flap and door, > 50 °C
  16. Time variation cca (±): 0.4 °C
  17. Space deviation cca (±) % of the reached temperature: 2.5 % 
  18. Time required to reach 250 °C with closed air flap and voltage 230 V: 64 min
  19. Heat emission at 250 °C: 2550 W
  20. Air exchange speed at 250 °C: 12 cycles/hour
  21. Electrical supply: mains 50/60 Hz
  22. Max. power input: 4.9 kW
  23. Nominal voltage: 400 / 3N V
  24. Current: 7.8 A
  25. Stand-by power consumption: 5 W 
Note:  Approx. 50 % of the tray area can be filled in a way a uniform air circulation is enabled inside the chamber.Note: All technical data are related to 22 °C of ambient temperature and ±10 % voltage swing rate ventilator 100 %, defrost off, lighting off.

Changes in the design and make reserved.
The values may differ depending on specific charge and media parameters.

JAKARTA

BIZ PARK PIK2, Blok C1/5 Tanjung Burung, Kec. Teluknaga, Kabupaten Tangerang, Banten

Komplek Griya Kemayoran Jl Industri 9-11 Komplek GK SB-3 Gunung Sahari Utara, Sawah Besar Jakarta Pusat 10720 DKI Jakarta. Telp 021-62302799 Fax (021) -62302799 HP/WA: (+62) 812-70868021

PEKANBARU

Jl. Jenderal No 43E Labuh Baru Timur, Kecamatan Payung Sekaki, Kota Pekanbaru 28291, Telp 0761-8366396 Email: triasnathomichemindo.pt@gmail.com

HP/WA: 081270868021

BATAM

Address Komplek Ruko Taman Niaga Sukajadi Blok K No. 11 Batam Centre – Batam Island Telp (+62)778 – 4800510, HP/WA: ,- 081270868021 

Produk Terbaru Lainnya:

Share this product :