Showing posts with label Auto Analyzer. Show all posts

Medium size constant temperature chamber Invitro box iB-230

Harga: Call Us
Medium size constant temperature chamber Invitro box iB-230


Inside and outside are stainless made. For refrigerator & a chamber for chromatography.

Main Application

Store of sample and reagent
Incubation of microorganisms and plant cells in combination with shaker
Immunoprecipitation in combination with rotator

Features

Small device such as shaker can be used inside chamber

Can be adapted to various experiments by combining with shaker and rotator. It has outlet for device inside chamber and has connection hole for power cable to go out.
・For incubation of anaerobic microorganism and immnoprecipitation at 4ºC
・For incubation of aerobic microorganism at +37ºC
・For western blotting and incubation during ELISA at 4ºC
(*) Please put shaker at bottom of the chamber when operating high speed shaking using reciprocal or rotary shaker.

Inside and outside are stainless made

Both inside and outside are made of stainless steel (SUS304), which has high durability and is easy to clean. It is easy to perform small scale protein purification in combination with a chromatography holder and a peristaltic pump.

Example of use



Energy saving temperature control method

The temperature regulation method saves energy and it is superior to conventional methods. The unit is also
equipped a freezer switch to switch it off when in use of temperature above ambient (+7℃ ).
It allows the unit to operate by a heater only s witching off the freezer.


Specifications


ModeliB-230
Temperature Range+3ºC - +45ºC
Temp. Control Accuracy±1.0 - 2.0℃(*1)
CapacityApprox. 230L
Heater700W
Cooler130W
Inside outlet2 (up to 3A)
Agitation methodForced agitation
Shelving/ load limit2, 60kg each (uniform load)
Power SupplyAC100V 8A (*2)
Usable dimensions600 x 440 x 870Hmm
Dimensions670 x 650 x 1475Hmm
WeightApprox. 90kg
Standard AccessoryShelf x 2, drain tray x 1, door key x 2
(*1) When environmental temperature is +25ºC. Operative temperature of this product is +5ºC - +30ºC.
(*2) In the case of using outlet inside chamber, electrical capacity increase depending on devices used.


Dimensions

Harga: Call Us
Medium size constant temperature chamber Invitro box iB-230


Inside and outside are stainless made. For refrigerator & a chamber for chromatography.

Main Application

Store of sample and reagent
Incubation of microorganisms and plant cells in combination with shaker
Immunoprecipitation in combination with rotator

Features

Small device such as shaker can be used inside chamber

Can be adapted to various experiments by combining with shaker and rotator. It has outlet for device inside chamber and has connection hole for power cable to go out.
・For incubation of anaerobic microorganism and immnoprecipitation at 4ºC
・For incubation of aerobic microorganism at +37ºC
・For western blotting and incubation during ELISA at 4ºC
(*) Please put shaker at bottom of the chamber when operating high speed shaking using reciprocal or rotary shaker.

Inside and outside are stainless made

Both inside and outside are made of stainless steel (SUS304), which has high durability and is easy to clean. It is easy to perform small scale protein purification in combination with a chromatography holder and a peristaltic pump.

Example of use



Energy saving temperature control method

The temperature regulation method saves energy and it is superior to conventional methods. The unit is also
equipped a freezer switch to switch it off when in use of temperature above ambient (+7℃ ).
It allows the unit to operate by a heater only s witching off the freezer.


Specifications


ModeliB-230
Temperature Range+3ºC - +45ºC
Temp. Control Accuracy±1.0 - 2.0℃(*1)
CapacityApprox. 230L
Heater700W
Cooler130W
Inside outlet2 (up to 3A)
Agitation methodForced agitation
Shelving/ load limit2, 60kg each (uniform load)
Power SupplyAC100V 8A (*2)
Usable dimensions600 x 440 x 870Hmm
Dimensions670 x 650 x 1475Hmm
WeightApprox. 90kg
Standard AccessoryShelf x 2, drain tray x 1, door key x 2
(*1) When environmental temperature is +25ºC. Operative temperature of this product is +5ºC - +30ºC.
(*2) In the case of using outlet inside chamber, electrical capacity increase depending on devices used.


Dimensions

WA-KAMI DETAIL

Kjeldahl Auto Analyzer and Distilation

Rp56,2Jt-75Jt
Model: TRAKA-11

PRODUCT OVERVIEW

Automatic Kjeldahl Analyzer is an automatic device integrating distillation and titration functions designed based on classic Kjeldahl nitrogen determination method.

It’s equipped with the latest core control system, powerful automatic degree and high-quality components, can easily achieve automatic waste discharge and cleaning of boiling tubes and titration cups, control steam supply and have real time detection of condensation temperature. High-accuracy charging pump and titration system ensure test process.

Titration Precision as high as 1.0uL/step TRAKA-11 Auto Kjeldahl analyzer has exclusive design i.e. linear motor micro-control titration system which ensures accurate results; the external use is easy for the observation of the accurate results; the external use is easy for the observation of the whole titration process; the built-in high-sensibility color sensing unit ensures accurate final point determination; extremely high-precision plunger titration unit achieves unprecedented precision as high as 1.0uL/step.


CHARACTERISTIC


  • Automatic completion of distillation, titration, calculation printing, waste discharge and cleaning.
  • External titration cup design gives operator real-time control of the whole test process.
  • Large LCD touch screen gives visual operation and abundant information, enabling user to have a good command of it.


Scope of application AKA-11 Auto Analyzer is widely used in food processing , feed production, tobacco, livestock, soil fertility, environmental monitoring, medicine, agriculture, scientific research, teaching, quality control & other fields for the test of nitrogen or protein content, can also be used for the test of ammonium, volatile fatty acid/ alkali, & so on.

TECHNICAL SPECIFICATION

Model
TRAKA-11
Sample capacity
Solid ≤5g /sample, liquid ≤20mL/Sample
Measuring Range
0.1mg N – 200mg N
Analysis time
5 – 10 min/sample
Recovery
≥99.5%
Burette volume
1.0uL/Step
Reproducibility
Average value relative error 0.5%
Storage Capacity
1000 pieces
Interface
USB or RS485
Power supply
220V 50Hz / 2KW
Water Consumption in the distillation process
1.5L/min
Cooling water temperature
˂20°C
Ambient temperature
10°C - 28°C



Rp56,2Jt-75Jt
Model: TRAKA-11

PRODUCT OVERVIEW

Automatic Kjeldahl Analyzer is an automatic device integrating distillation and titration functions designed based on classic Kjeldahl nitrogen determination method.

It’s equipped with the latest core control system, powerful automatic degree and high-quality components, can easily achieve automatic waste discharge and cleaning of boiling tubes and titration cups, control steam supply and have real time detection of condensation temperature. High-accuracy charging pump and titration system ensure test process.

Titration Precision as high as 1.0uL/step TRAKA-11 Auto Kjeldahl analyzer has exclusive design i.e. linear motor micro-control titration system which ensures accurate results; the external use is easy for the observation of the accurate results; the external use is easy for the observation of the whole titration process; the built-in high-sensibility color sensing unit ensures accurate final point determination; extremely high-precision plunger titration unit achieves unprecedented precision as high as 1.0uL/step.


CHARACTERISTIC


  • Automatic completion of distillation, titration, calculation printing, waste discharge and cleaning.
  • External titration cup design gives operator real-time control of the whole test process.
  • Large LCD touch screen gives visual operation and abundant information, enabling user to have a good command of it.


Scope of application AKA-11 Auto Analyzer is widely used in food processing , feed production, tobacco, livestock, soil fertility, environmental monitoring, medicine, agriculture, scientific research, teaching, quality control & other fields for the test of nitrogen or protein content, can also be used for the test of ammonium, volatile fatty acid/ alkali, & so on.

TECHNICAL SPECIFICATION

Model
TRAKA-11
Sample capacity
Solid ≤5g /sample, liquid ≤20mL/Sample
Measuring Range
0.1mg N – 200mg N
Analysis time
5 – 10 min/sample
Recovery
≥99.5%
Burette volume
1.0uL/Step
Reproducibility
Average value relative error 0.5%
Storage Capacity
1000 pieces
Interface
USB or RS485
Power supply
220V 50Hz / 2KW
Water Consumption in the distillation process
1.5L/min
Cooling water temperature
˂20°C
Ambient temperature
10°C - 28°C