PT.TRIAS NATHOMI CHEMINDO, JAKARTA-021-62302799, HP/WA: 081270868021; Email: triasnathomichemindo.pt@gmail.com| KUNJUNGI KAMI DALAM PAMERAN LAB EXPO 2022- JCC BOOTH L-23 (7 - 9 SEPT 2022) , KUNJUNGI KAMI DALAM PAMERAN INARI EXPO 2022, GEDUNG ICC (CIBINONG SCIENCE CENTRE-CIBINONG 27-30 OKTOBER 2022
Produk Terbaru
Showing posts with label gc. Show all posts
Showing posts with label gc. Show all posts

Gas Chromatography-1290

 

GC-1290

 

GC-1290
WA-KAMI DETAIL

Gas Chromatography

 
GC-1120
 
GC-1120
WA-KAMI DETAIL

ISOCRATIC HPLC TRLT-LC100

Rp.126Jt-135Jt
TRLT-LC100

ScienNovo LT-LC100 Isocratic High Pressure Liquid Chromatography (HPLC)

Flexible Configuration
TRLT-LC100 system offers analytical flexibilty. It provides a comprehensive selection that can be combined to make up a variety of system for different demands.


  • Choice of pumping system
  • Isocratic system
  • High-pressure binary gradient system
  • Sale-clen function operational
  • Choice of detection system
  • UV Detector for routine analysis
  • RID for universal detection in isocratic analysis, especially necessary in GPC system
  • ELSD for universal detection, especially necessary in standard methods in pharmacopeia of China

Features and Benefits
All maintenance parts are accessible from the front panel for quick replacement without disassembling instrument.
The monitoring system will stop the pump if pre-limit pressure is exceeded.
All components are controlled intelligently in workstation.
Multiple data analysis functions, including six quantitative algorithmic methods, flexible peak identification and isposal, etc.

SPCIFICATIONS

Pump
Specifications
Flow rate range
0.001-9.999mL/min
Flow rate accuracy
≤±1%(1mL/min, water, room temperature)
Flow rate precision
RSD≤0.1%(1mL/min, water, room temperature)
Peak operating pressure
42MPa
Power source
110V/220V


UV Detector
Specifications
Lamp
D2
Wavelengthe range
190-680nm
Baseline noise
≤±1×10-5AU
Baseline drift
≤2×10-4AU/h
Limit of detection
1×10-8 g/ml(Naphthalene/methyl alcohol solvent)
Volume of flow cell
8μL
Wavelength precision
≤0.2nm
Wavelength accuracy
±1nm
Power source
110V/220
 
Configuration
QTY
Pump
1pcs
UV Detector
1pcs
7725iSix-way valve
1pcs
workstation
1pcs
C18 Column,250*4.6mm
1pcs
Rp.126Jt-135Jt
TRLT-LC100

ScienNovo LT-LC100 Isocratic High Pressure Liquid Chromatography (HPLC)

Flexible Configuration
TRLT-LC100 system offers analytical flexibilty. It provides a comprehensive selection that can be combined to make up a variety of system for different demands.


  • Choice of pumping system
  • Isocratic system
  • High-pressure binary gradient system
  • Sale-clen function operational
  • Choice of detection system
  • UV Detector for routine analysis
  • RID for universal detection in isocratic analysis, especially necessary in GPC system
  • ELSD for universal detection, especially necessary in standard methods in pharmacopeia of China

Features and Benefits
All maintenance parts are accessible from the front panel for quick replacement without disassembling instrument.
The monitoring system will stop the pump if pre-limit pressure is exceeded.
All components are controlled intelligently in workstation.
Multiple data analysis functions, including six quantitative algorithmic methods, flexible peak identification and isposal, etc.

SPCIFICATIONS

Pump
Specifications
Flow rate range
0.001-9.999mL/min
Flow rate accuracy
≤±1%(1mL/min, water, room temperature)
Flow rate precision
RSD≤0.1%(1mL/min, water, room temperature)
Peak operating pressure
42MPa
Power source
110V/220V


UV Detector
Specifications
Lamp
D2
Wavelengthe range
190-680nm
Baseline noise
≤±1×10-5AU
Baseline drift
≤2×10-4AU/h
Limit of detection
1×10-8 g/ml(Naphthalene/methyl alcohol solvent)
Volume of flow cell
8μL
Wavelength precision
≤0.2nm
Wavelength accuracy
±1nm
Power source
110V/220
 
Configuration
QTY
Pump
1pcs
UV Detector
1pcs
7725iSix-way valve
1pcs
workstation
1pcs
C18 Column,250*4.6mm
1pcs
WA-KAMI DETAIL