DIGITAL VERNIER CALIPER TR-6333645



TR-6333645

DIGITAL VERNIER CALIPER TR-6333645

Take easy and accurate measurements with our digital caliper. Accuracy to 0.001” with a resolution to 0.0005”. Features both metric and SAE readouts. Steel jaws are precision ground.




TR-6333645

DIGITAL VERNIER CALIPER TR-6333645

Take easy and accurate measurements with our digital caliper. Accuracy to 0.001” with a resolution to 0.0005”. Features both metric and SAE readouts. Steel jaws are precision ground.


WA-KAMI DETAIL

Aluminum block bath Dry thermo unit DTU-Neo

Harga: Call Us
Aluminum block bath Dry thermo unit DTU-Neo

Aluminum block bath Dry thermo unit DTU-Neo


Applicable to isothermal gene amplification by programming. Quick temperature transition, a lot of exchange block.


Operation panel

Main Application

Various enzyme reaction and heat denaturation DNA/RNA

Features

Large enough size for half block x 2 or full block x 1

It can have one of Full block which can have 40 of 1.5ml micro tubes. It also can have two of Half block which is common use with Mini and can use two types of container.

Meet to various containers with exchanging block

We have a several half blocks (option) to meet with various containers. Full block for 0.2ml micro tube can have PCR plate as well. For detail please see next page.

Two types with different temperature range, Cooling type adopts Peltier system

There are DTU-Mini which is usable from Room temperature +3ºC, CTU-Mini which can handle low temperature by cooling with environmental friendly and energy saving Peltier heating and cooling system. Either one have improved temperature transition velocity.

Temperature programming with wait function

Wait function which wait timer count until temperature reach to setting value is equipped. Together with improved temperature transition velocity, it can perform accurate temperature change at isothermal gene amplification.


Specifications

ModelDTU-Neo
Temperature RangeRT+3ºC - +105 ºC
Temp. Control Accuracy±0.1ºC - +0.2 ºC
Temperature transition time (environmental temperature: +25 ºC)20ºC --> 100ºC/ about 20min(when using B-1140)
100ºC --> 25ºC/ about 60min(when using B-1140)
Minimum temperature setting unit0.1ºC
Temperature settingUp and down setting
Temperature DisplayDigital display (setting temperature and current temperature)
Heating-Cooling SystemHeat by heater, radiation by fun
Programming Function2memory, 9 segment, wait function, setting time: 0 - 99hrs 59min
Safety device / functionFuse, overvoltage protection, over current protection, overheat, sensor error, nonvolatile memory error, protection of sample (high/low temperature), high temperature cutout
Dimensions210 x 268 x 175Hmm
WeightApprox. 4kg (exclude block)
Power SupplyAC100V 2A
Standard AccessoryHook handle for taking block out

With open cover and environment over +30ºC, sometimes specifications doesn’t meet.


Harga: Call Us
Aluminum block bath Dry thermo unit DTU-Neo

Aluminum block bath Dry thermo unit DTU-Neo


Applicable to isothermal gene amplification by programming. Quick temperature transition, a lot of exchange block.


Operation panel

Main Application

Various enzyme reaction and heat denaturation DNA/RNA

Features

Large enough size for half block x 2 or full block x 1

It can have one of Full block which can have 40 of 1.5ml micro tubes. It also can have two of Half block which is common use with Mini and can use two types of container.

Meet to various containers with exchanging block

We have a several half blocks (option) to meet with various containers. Full block for 0.2ml micro tube can have PCR plate as well. For detail please see next page.

Two types with different temperature range, Cooling type adopts Peltier system

There are DTU-Mini which is usable from Room temperature +3ºC, CTU-Mini which can handle low temperature by cooling with environmental friendly and energy saving Peltier heating and cooling system. Either one have improved temperature transition velocity.

Temperature programming with wait function

Wait function which wait timer count until temperature reach to setting value is equipped. Together with improved temperature transition velocity, it can perform accurate temperature change at isothermal gene amplification.


Specifications

ModelDTU-Neo
Temperature RangeRT+3ºC - +105 ºC
Temp. Control Accuracy±0.1ºC - +0.2 ºC
Temperature transition time (environmental temperature: +25 ºC)20ºC --> 100ºC/ about 20min(when using B-1140)
100ºC --> 25ºC/ about 60min(when using B-1140)
Minimum temperature setting unit0.1ºC
Temperature settingUp and down setting
Temperature DisplayDigital display (setting temperature and current temperature)
Heating-Cooling SystemHeat by heater, radiation by fun
Programming Function2memory, 9 segment, wait function, setting time: 0 - 99hrs 59min
Safety device / functionFuse, overvoltage protection, over current protection, overheat, sensor error, nonvolatile memory error, protection of sample (high/low temperature), high temperature cutout
Dimensions210 x 268 x 175Hmm
WeightApprox. 4kg (exclude block)
Power SupplyAC100V 2A
Standard AccessoryHook handle for taking block out

With open cover and environment over +30ºC, sometimes specifications doesn’t meet.


WA-KAMI DETAIL

HALOES CALIPER - ZONE READER

Harga: CALL US
TR-900

 PRODUCT OVERVIEW

Making a precise inhibition zone measurement (100 µm resolution) manually can become a challenge. The Haloes Caliper helps to perform this in a simple and precise fashion while avoiding parallax errors in readings. Pharmaceutical and clinical labs involved in inhibition zone measurements benefit from the use of this device. A precision rotating wheel accurately measures inhibition zones while being manually spun. This comes in handy during antibiotic susceptibility testing and antibiotic potency measurements.

SYSTEM HIGHLIGHTS
  • High resolution: The Haloes Caliper has a 100 µm resolution.
  • No parallax error: The Haloes Caliper’s exclusive screen-lense system avoids missing the ends of the haloes through its unique perpendicular reading technology.
  • Clear display of results: Results will be clearly featured in a digital display.

TECHNICAL DATA
  1. Magnification: Factor 2.25
  2. Measuring range: 0-35mm
  3. Resolution: 0.1mm
  4. Mains: 100/240V 50/60Hz
  5. Power: 50W
  6. Dimensions (WxDxH): 27x23x27cm / 10.6x9.0x10.6 in
  7. Weight: 3 kg / 6.6 lb
Specifications subject to change without notice
Harga: CALL US
TR-900

 PRODUCT OVERVIEW

Making a precise inhibition zone measurement (100 µm resolution) manually can become a challenge. The Haloes Caliper helps to perform this in a simple and precise fashion while avoiding parallax errors in readings. Pharmaceutical and clinical labs involved in inhibition zone measurements benefit from the use of this device. A precision rotating wheel accurately measures inhibition zones while being manually spun. This comes in handy during antibiotic susceptibility testing and antibiotic potency measurements.

SYSTEM HIGHLIGHTS
  • High resolution: The Haloes Caliper has a 100 µm resolution.
  • No parallax error: The Haloes Caliper’s exclusive screen-lense system avoids missing the ends of the haloes through its unique perpendicular reading technology.
  • Clear display of results: Results will be clearly featured in a digital display.

TECHNICAL DATA
  1. Magnification: Factor 2.25
  2. Measuring range: 0-35mm
  3. Resolution: 0.1mm
  4. Mains: 100/240V 50/60Hz
  5. Power: 50W
  6. Dimensions (WxDxH): 27x23x27cm / 10.6x9.0x10.6 in
  7. Weight: 3 kg / 6.6 lb
Specifications subject to change without notice